Application Fields Of Integrated Sewage Treatment Equipment

Apr 04, 2026

Leave a message

The primary treatment method employed is the biochemical contact oxidation process. The integrated domestic sewage treatment unit is designed to handle domestic sewage-as well as similar types of industrial organic wastewater-with water quality parameters calculated based on typical domestic sewage standards; the influent BOD5 concentration is assumed to be 200 mg/L.


The main components of the system are: 1. Hydrolysis-Acidification Tank; 2. Contact Oxidation Tank; 3. Impurity Sedimentation Tank; 4. Disinfection Unit; 5. Aerobic Sludge Digestion Tank.

 

1. Hydrolysis-Acidification Tank
The primary function of this stage is to serve as a pretreatment step for the wastewater. It facilitates a degree of anaerobic fermentation within the wastewater, thereby enhancing its biodegradability. This constitutes a critical preliminary step in the treatment process, as it directly influences the efficiency and duration of the subsequent treatment stages, ultimately maximizing overall treatment efficiency while minimizing resource consumption.

 

2. Contact Oxidation Tank
The oxidation tank is categorized into several grades-specifically "Standard" and "Enhanced" types-depending on the degree of wastewater contamination requiring treatment. The selection between these types is typically determined by the required treatment duration: the Standard type is utilized when the treatment time does not exceed four hours, whereas the Enhanced type is employed for treatment durations ranging from four to six hours. In this stage, the effluent from the Hydrolysis-Acidification Tank flows by gravity into the Contact Oxidation Tank for biochemical treatment. The majority of the organic matter present in the raw sewage is degraded and purified within this tank. Aerobic bacteria, utilizing the packing material as a substrate, consume the organic matter in the wastewater and decompose it into inorganic salts, thereby achieving the objective of purification. The survival of these aerobic bacteria necessitates an adequate supply of oxygen-specifically, a sufficient concentration of dissolved oxygen within the wastewater-to ensure the successful execution of the biochemical treatment process. Air is supplied to the aerobic tank via blowers. The tank is equipped with a novel type of elastic, three-dimensional packing material, which features a large specific surface area, a long service life, excellent biofilm attachment properties, and corrosion resistance. Furthermore, the tank bottom utilizes rotary-mixing aerators to ensure a high dissolved oxygen transfer rate; these aerators offer additional advantages such as light weight, resistance to aging, minimal clogging risk, and a long operational lifespan. The typical air-to-water ratio within the contact oxidation tank is approximately 12:1. (For contact tanks with a capacity of 0.5–5 m³/h, a two-stage configuration is utilized.)

 

3. Impurity Sedimentation Tank
After undergoing treatment in the biological contact oxidation tank, the effluent flows by gravity into the sedimentation tank. Here, further sedimentation occurs to remove detached biofilms as well as small organic and inorganic particles. The sedimentation tank operates on the principle of gravity: as wastewater containing suspended solids flows upward through the tank, gravitational forces cause the solid matter to settle out. An adjustable effluent weir is installed at the top of the tank to regulate the water level, while the lower section features a conical sedimentation zone and a sludge aeration system. Air is supplied by a blower, and the sludge is transported via an air-lift mechanism to the aerobic sludge digestion tank.

 

4. Disinfection Treatment
The disinfection tank is designed to provide a retention time of 30 minutes, in accordance with the standard specified in *TJ14-74*. For hospital wastewater, this retention time is increased to 1–1.5 hours. Our company employs a chlorine dioxide disinfection system; the disinfection tank and dosing unit are designed to dynamically adjust the chemical dosage based on the effluent flow rate-increasing the dosage when flow is high and decreasing it when flow is low. Other disinfection systems can be provided upon request. (Note: If the system is intended for industrial wastewater treatment, the disinfection tank and associated dosing unit may be omitted.)

 

5. Aerobic Sludge Digestion Tank
Surplus sludge discharged from the sedimentation tank undergoes aerobic digestion and stabilization within this tank, thereby reducing the sludge volume and enhancing its stability. Following aerobic digestion, the volume of residual sludge is significantly reduced. For removal, a vacuum truck can be used to extract the sludge: the suction hose is inserted through an inspection port at the top of the tank down to the bottom, and the extracted sludge is then transported off-site for disposal (cleaning is typically required once every six months). The upper section of the aerobic sludge digestion tank is equipped with a supernatant recirculation device, allowing the clarified supernatant to overflow into the hydrolysis and acidification tank.

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!