Core Classification and Functions of Water Treatment Structures
Water treatment structures serve as the physical vessels for the treatment or purification of wastewater. Based on the specific treatment processes employed, they can be broadly categorized into the following three types:
Physical Treatment Structures: These remove impurities through physical means such as gravity, screening, and filtration. Examples include:
Screens/Grit Racks: Designed to intercept large suspended solids; the spacing between the bars typically ranges from 5 to 20 mm (per the *Standard for Design of Outdoor Drainage* [GB50014-2021]).
Grit Chambers: Designed to remove sand particles larger than 0.2 mm, with a typical hydraulic retention time of approximately 30 to 60 seconds.
Sedimentation Tanks: Classified into horizontal-flow types (with a surface loading rate of 1.0–3.0 m³/(m²·h)) and vertical-flow types (with an upward flow velocity of 0.3–0.5 mm/s).
Chemical Treatment Structures: These include coagulation tanks (involving the addition of coagulants such as PAC/PAM) and disinfection tanks (requiring a chlorine contact time of ≥ 30 minutes), among others.
Biological Treatment Structures: Examples include aeration tanks utilized in the activated sludge process (typically maintaining a sludge concentration of 2,000–4,000 mg/L) and biofilters (operating with a loading rate of 0.1–0.4 kg BOD₅/m³·d).
Design and Expanded Applications of Typical Structures
High-Efficiency Variants of Filtration Tanks:
V-Type Filters: Characterized by a filtration rate of 6–10 m/h and a backwash intensity of 15 L/(m²·s).
Activated Carbon Filters: Employ activated carbon with an iodine value of ≥ 1,000 mg/g; typically utilized for advanced (tertiary) water treatment.
Membrane Treatment Units: Feature ultrafiltration membranes with pore sizes ranging from 0.01 to 0.1 μm and a flux rate of 50–100 LMH (liters per square meter per hour).
Structures Utilizing Emerging Technologies: Examples include constructed wetlands (operating with a hydraulic loading rate of 5–10 cm/d) and magnetic separation tanks (utilizing a magnetic field strength of 0.5–1.0 T).
Selection Criteria and Technical Basis for Parameters
Key data are referenced from the *Handbook of Water Supply and Drainage Design* and EPA standards; for example:
Surface loading rate for secondary sedimentation tanks: 0.6–1.2 m³/(m²·h) for the activated sludge process;
For the AAO process, the Hydraulic Retention Time (HRT) is 1–2 hours in the anaerobic zone and 4–8 hours in the aerobic zone.
For actual engineering projects, the design must be adjusted based on specific water quality characteristics (e.g., intensified pretreatment is required when COD exceeds 300 mg/L).